STRUCTURE, FUNCTION AND MAINTENANCE STANDARD COOLING FAN MOTOR 1. Hydraulic motor unit Function This hydraulic motor is called a swash plate-type axial piston motor. It converts the energy of the pressurized oil sent from the hydraulic pump into rotary motion. Principle of operation The oil sent from the hydraulic pump flows through valve plate (7) into cylinder block (5). This oil can flow on only 1 side of the Y-Y line connecting the top dead center and bottom dead center of the stroke of piston (4). The oil sent to 1 side of cylinder block (5) presses pistons (4) (4 or 5 pieces) and gener- ates force F1 ( F1 kg = P kg/cm 2 x /4D 2 cm 2 ). This force is applied to thrust plate (2).
Since thrust plate (2) is fixed to the angle of degrees to the output shaft (1), the force is divided into components F2 and F3 . The radial component F3 generates torque against the Y-Y line connecting the top dead cen- ter and bottom dead center ( T = F3 x ri ). The resultant of this torque [ T = ( F3 x ri )] rotates the cylinder block (5) through the piston. Since the cylinder block (5) is coupled with the output shaft by means of spline, the output shaft revolves to transmit the torque. 10-128 D85EX-15