Komatsu — PPC VALVE

STRUCTURE, FUNCTION AND MAINTENANCE STANDARD PPC VALVE 2. During fine control (Neutral fine control) When piston (4) is pushed by disc (5), retainer (9) is pushed, and spool (1) is also pushed through metering spring (2), and moves down. As a result, if fine control hole f is shut off from drain chamber D , at almost the same time, it is connected with pump pressure chamber PP , and the pilot pressure oil passes through fine control hole f and flows from port P1 to port PA3 .

When the pressure at port P1 becomes high, if spool (1) is pushed back and fine control hole f is shut off from pump pressure chamber PP , at almost the same time, it is connected with drain chamber D and released the pressure at port P1 . As a result, spool (1) moves up and down so that the force of metering spring (2) is balanced with the pressure at port P1 . The relation between the positions of spool (1) and body (10) (fine control hole f is at the midpoint between drain chamber D and pump pressure chamber PP ) does not change until retainer (9) contacts spool (1).

Therefore, metering spring (2) is compressed an amount proportional to the movement of the con- trol lever, so the pressure at port P1 also rises in proportion to the movement of the control lever. The control valve spool moves to a position where the pressure in chamber PA3 (same as pressure at port P1 ) is balanced with the force of the return spring. 3. During fine control (when control lever is returned) When disc (5) starts to be returned, spool (1) is pushed up by the pressure at port P1 and the force of centering spring (3). As a result, fine control hole f is connected to drain chamber D , so the pressure oil at port P1 is relieved.

If the pressure at port P1 goes down to far, spool (1) is pushed down by metering spring (2). Fine control hole f is shut off from drain chamber D , and at almost the same time, it is connected to pump pressure chamber PP . Pump pressure is supplied until the pressure at port P1 recovers to a pressure equivalent to the position of the lever. When the control valve spool returns, the oil at drain chamber D flows in from fine control hole f' in the valve on the side that is not moving. It passes through port P2 , is taken to chamber PB3 , and the oil fills the chamber. D85EX-15 10-143