STRUCTURE, FUNCTION AND MAINTENANCE STANDARD PPC VALVE 4. When lever is operated fully When disc (5) pushes down piston (4) and retainer (9) pushes down spool (1), fine control hole f is shut off from drain chamber D and is connected to pump pressure chamber PP . Therefore, the pilot pressure oil passes through fine control hole f , is taken from port P1 to cham- ber PA3 , and pushes the control valve spool. The return oil from chamber PB3 passes from port P2 through fine control hole f' , and then flows to drain chamber D . 5.
When blade is operated to FLOAT When piston (4) at the port P1 LOWER side is pushed by disc (5) and moves down, ball (11) contacts protrusion a of the piston during the stroke. (Detent starts to act. ) When piston (4) pushed in further, ball (11) pushes up collar (12), which is being held by detent spring (13). While pushing up collar (12), it escapes to the outside and passes over protru- sion a of the piston. When this happens, piston (4') on the opposite side is pushed up by spring (14). As a result, the oil inside chamber F passes through b and c , and flows to chamber E , and piston (4') follows disc (5).
Passage d is con- nected to port P1 , so more or less the same pressure is applied as is applied to port P1 . Chamber E is normally connected to drain chamber D , but if ball (11) passes over protru- sion a of the piston, passage d and chamber E , which were shut off, are connected and the pres- sure oil flows. At the same time, the control valve also moves to the FLOAT position and the circuit is set to the FLOAT condition. Piston (4') is being pushed up by the oil pressure inside chamber E , so even if the lever is released, it is held at the FLOAT position. 10-144 D85EX-15