Komatsu — PPC VALVE

STRUCTURE, FUNCTION AND MAINTENANCE STANDARD PPC VALVE Operation 1. At neutral P1 and P2 ports of the operation valves A , B and PPC valve are connected to drain room D via the fine control hole f on the spool (1). 2. During fine control (Neutral fine control) As the piston (4) is pushed by disk (5), the retainer (7) is pushed too. At the same time, the spool (1) is also pushed down via the metering spring (2). By this move, connection of the fine control hole f is switched from the drain room D to the pump pressure room PP , and pilot pressure oil is con- ducted from P1 port to A port. As P1 port pressure increases, the spool (1) is pushed back.

By this move, connection of the fine control hole f is switched from the pump pressure room PP to the drain room D , thereby relieving P1 port pressure. As the result, the spool (1) moves up and down so that force of the metering spring (2) and P1 port pressure may be balanced. Positional relationship between the spool (1) and body (8) (fine control hole f is situated at mid point between the drain room D and pump pres- sure room PP ) remains unchanged until the retainer (7) is contacted against the spool (1). The metering spring (2) is, therefore, com- pressed in proportion to strokes of the operation lever.

Thus, the P1 port pressure too, increases in proportion to strokes of the operation lever. As the result, the operation valve spool moves to the position where the pressure of A room (the same as P1 port pressure) is balanced against force of the operation valve spool return spring. 10-148 D85EX-15