Komatsu — PPC VALVE

STRUCTURE, FUNCTION AND MAINTENANCE STANDARD PPC VALVE 3. During fine control (when control lever is returned) As the lever (5) starts returning, the spool (1) is pushed up by force of the centering spring (3) and P1 port pressure. By this move, the fine con- trol hole f is connected to the drain room D and relieves pressurized oil of P1 port to it. If P1 port pressure goes excessively low, the spool (1) is pushed down by the metering spring (2), and passage between fine control hole f and drain room D is shut down. And, almost at the same time, the hole is connected to the pump pressure room PP and starts supplying pump the pressure.

This supply continues until the P1 port pressure is recovered to the level equivalent to the lever position. When the operation valve spool returns, oil in the drain room D flows in through the fine control hole on the not moving side valve. Oil is then conducted via P2 port to the room B to fill it up. 4. At full stroke When the disk (5) pushes down piston (4) and the retainer (7) pushes down the spool (1), con- nection of the fine control hole f is switched from the drain room D , to the pump pressure room PP . Thus, pilot pressurized oil from the control pump passes through fine control hole f and conducted to A room via P1 port to push the operation valve spool.

Return oil from B room is conducted from P2 port to the drain room D via the fine control hole . D85EX-15 10-149