STRUCTURE, FUNCTION AND MAINTENANCE STANDARD PPC VALVE 1. Spool 2. Metering spring 3. Centering spring 4. Piston 5. Disc 6. Nut (for lever connection) 7. Joint 8. Plate 9. Retainer 10. Body 11. Filter Unit: mm No. Remedy 12 Replace spring if damaged or deformed 13 14 D85EX-15 10-151 Check item Criteria Centering spring (for P3, P4) Standard size Installed Installed Free length length load 55.9 N 50.4 × 15.5 34 {5.7 kg} Repair limit Installed Installed length load Free length Installed load 55.9 N 34 {5.7 kg} – 44.7 {4.56 kg} Centering spring (for P1, P2) 50.1 × 15.5 71.4 N 34 {7.28 kg – } 56.9 N {5.8 kg} Metering spring 26.5 × 8.20 16.7 N 24.9 {1.7 kg} – 13.3 N {1.36 kg}