Komatsu — PPC VALVE

STRUCTURE, FUNCTION AND MAINTENANCE STANDARD PPC VALVE OPERATION 1. At neutral Ports A and B of the control valve and ports P1 , P2 , P3 , and P4 of the PPC valve are connected to drain chamber D through fine control hole f of spool (1). (Fig. 1) 2. Fine control (neutral fine control) When piston (4) starts to be pushed by disc (5), retainer (9) is pushed. Spool (1) is also pushed by metering spring (2) and moves down. When this happens, fine control hole f is shut off from drain chamber D . At almost the same time, it is connected to pump pressure chamber PP , and the pilot pressure is sent through fine control hole f from port P1 to port A .

When the pressure at port P1 rises, spool (1) is pushed back. Fine control hole f is shut off from pump pressure chamber PP . At almost the same time, it is connected to drain chamber D , so the pressure at port P1 escapes. As a result, spool (1) moves up and down until the force of metering spool (2) is balanced with the pressure of port P1 . The relationship of the positions of spool (1) and body (10) (fine control hole f is in the middle between drain hole D and pump pressure cham- ber PP ) does not change until retainer (9) con- tacts spool (1).

Therefore, metering spring (2) is compressed in proportion to the travel of the control lever, so the pressure at port P1 also rises in proportion to the travel of the control lever. In this way, the spool of the control valve moves to a position where the pressure of chamber A (same as pressure at port P1 ) and the force of the return spring of the control valve spool are balanced. (Fig. 2) 10-152 D85EX-15