Komatsu — PPC VALVE

STRUCTURE, FUNCTION AND MAINTENANCE STANDARD PPC VALVE 3. Fine control (control lever returned) When disc (5) starts to be returned, spool (1) is pushed up by the force of centering spring (3) and the pressure at port P1 . Because of this, fine control hole f is connected to drain chamber D , and the pressurized oil at port P1 is released. If the pressure at port P1 drops too much, spool (1) is pushed down by metering spring (2), so fine control hole f is shut off from drain chamber D . At almost the same time, it is connected to pump pressure chamber PP , so the pressure at port P1 supplies the pump pressure until the pressure recovers to a pressure equivalent to the position of the lever.

When the control valve spool returns, oil in drain chamber D flows in from fine control hole of the valve on the side that is not moving. It passes through port P2 and goes to chamber B to charge the oil. (Fig. 3) 4. At full stroke When disc (5) pushes down piston (4), and retainer (9) pushes down spool (1), fine control hole f is shut off from drain chamber D , and is connected to pump pressure chamber PP . Therefore, the pilot pressure oil is sent from port P1 through fine control hole f to port A to push the control valve spool. The return oil from chamber B passes from port P2 and flows through fine control hole to drain chamber D . (Fig. 4) D85EX-15 10-153