Komatsu — SELF PRESSURE REDUCING VALVE

STRUCTURE, FUNCTION AND MAINTENANCE STANDARD SELF PRESSURE REDUCING VALVE 2. When the load pressure P2 is lower than the output pressure PR of the self pressure reducing valve. The spring (3) and the PR pressure (0 MPa {0 kg/cm 2 } at the time of engine stop) pushes the valve (2) in the direction to close the circuit between the ports P1 and P2 . When the hydraulic oil enters the P1 port, the expression ( P1 pressure Spring (7) force + (ш d area x PR pressure)) holds, and the self pressure reducing valve will adjust the openings of the ports P1 and P2 so that the P1 pressure can be maintained higher than the PR pressure.

When the PR pressure rises above the set pres- sure, the poppet (5) will open and the hydraulic oil flows through the route from the PR port, the hole a in the spool (8), the poppet (5) opening to the tank port T . Therefore, there will occur a differential pressure around the hold a in the spool (8) and the spool will move in the direction to close the port P1 and the PR opening. Then, the P1 pressure is reduced and adjusted to a certain pressure (set pressure) with the opening and is supplied as the PR pressure. D85EX-15 10-197