Komatsu — SELF PRESSURE REDUCING VALVE

STRUCTURE, FUNCTION AND MAINTENANCE STANDARD SELF PRESSURE REDUCING VALVE 3. At raise of load pressure P2 When the load pressure P2 rises due to digging or other operations, the pump delivery will increase and the P1 pressure will rise. Then, the expression ( P1 pressure > Spring (7) force + ( d area x PR pressure)) will hold, and the valve (2) will move to the right side till the stroke end. As a result, the opening between the ports P1 and P2 will increase, the passage resistance will become smaller to reduce engine loss horse- power.

When the PR pressure rises above the set pres- sure, the poppet (5) will open and the hydraulic oil will flow through the route from the PR port, the hole a in the spool (8), the poppet (5) open- ing to the tank port T . Therefore, there will occur a differential pressure around the hold a in the spool (8) and the spool will move in the direction to close the port P1 and the PR opening. Then, the P1 pressure is reduced and adjusted to a certain pressure (set pressure) with the opening and is supplied as the PR pressure. 10-198 D85EX-15