Komatsu — MEASURING EXHAUST TEMPERATURE

TESTING AND ADJUSTING MEASURING EXHAUST TEMPERATURE MEASURING EXHAUST TEM- PERATURE 4. Procedure for measuring maximum exhaust tem- perature for troubleshooting Operate the machine actually and measure the maximum exhaust temperature. a Use the PEAK mode of the digital thermome- ter. a The exhaust temperature largely depends on the outside air temperature (intake air tem- perature of the engine). Accordingly, if any abnormal value is obtained, correct it by the following calculation. Corrected value [°C] = Measured value + 2 x (20 – Outside air temperature) a Measuring instrument for exhaust temperature Install and remove the measuring instrument after the exhaust manifold is cooled.

a Measure the exhaust temperature under the fol- lowing condition. Engine water temperature: Within operating range Power train oil temperature: Within operating range Hydraulic oil temperature: Within operating range 1. Open the right side cover of the engine and remove turbocharger heat insulation cover (1). 5. Procedure for measuring exhaust temperature periodically for preventive maintenance a If the torque converter is stalled simply, the torque converter oil temperature is over- heated before the exhaust temperature is stabilized. Accordingly, measure according to the following procedure.

1) Stall the torque converter fully to raise the exhaust temperature to about 650ЧС accord- ing to the following procedure (Condition a in the figure). i) Start the engine and set the fuel control dial to the low idling position. Raise the ripper lift cylinder to the stroke end with the ripper lever. ii) Press the brake pedal securely and set the PCCS lever in the FORWARD 3rd gear speed position. iii) Press the decelerator pedal and set the fuel control dial to the high idling position. iv) Return the decelerator pedal slowly to stall the torque converter and relieve the ripper in raising direction with the engine at high idling. 2. Remove exhaust temperature pick-up plug (2). 3.

Install sensor [1] and connect them to digital thermometer B . a Clamp the wiring harness of the digital ther- mometer so that it will not touch a hot part during measurement. 20-110 D85EX-15 (1) Symbol Part No. Name B 799-101-1502 Digital thermometer