Komatsu — ADJUSTING VALVE CLEARANCE

TESTING AND ADJUSTING ADJUSTING VALVE CLEARANCE ADJUSTING VALVE CLEAR- ANCE a When the No. 1 cylinder is at the compres- sion top dead center, the rocker arms on both intake side and exhaust side can be moved by the valve clearance with the hand. If the rocker arms cannot be moved, rotate the crankshaft one more turn. a Adjusting instrument for valve clearance 1. Open the engine left side cover. 2. Remove air cleaner (1) and bracket (2). 3. Move bracket (3) back and remove air intake connector (8). 6. Insert filler gauge D in clearance "b" between rocker arm (4) and crosshead (5) and adjust the valve clearance with adjustment screw (6).

a With the filler gauge inserted, turn the adjust- ment screw so that you can move the filler gauge lightly. 7. Fixing adjustment screw (6), tighten locknut (7). Locknut: 53.0 – 64.7 Nm {5.4 – 6.6 kgm} 4. Remove all cylinder head covers (9). a The cylinder head covers cannot be removed completely because of the fuel high-pressure tube. Move them toward the air intake mani- fold without removing them from the tube. a After tightening the locknut, check the valve clearance again. 5. Rotate the crankshaft forward to bring the stamped 1.6TOP line a to pointer (10) and set the No. 1 cylinder to the top dead center. a Use the damper mounting bolt to rotate the crankshaft.

D85EX-15 20-113 (1) Symbol Part No. Name D Purchased Filler gauge