Komatsu — RELEASING RESIDUAL PRESSURE IN WORK EQUIPMENT CYLINDER

TESTING AND ADJUSTING RELEASING RESIDUAL PRESSURE IN WORK EQUIPMENT CYLINDER RELEASING RESIDUAL PRESSURE IN WORK EQUIPMENT CYLINDER RELEASING RESIDUAL PRESSURE IN WORK EQUIPMENT CYLINDER (If PPC accumulator is installed) (If PPC accumulator is not installed) a When disconnecting the piping between the con- trol valve and work equipment cylinder, release the residual pressure in the circuit according to the following procedure. a When disconnecting the piping between the con- trol valve and work equipment cylinder, release the residual pressure in the circuit according to the following procedure. 1. Loosen the hydraulic tank cap gradually to release the residual pressure in the tank. 1.

Run the engine at low idling and lower the blade and ripper to the ground without relieving each hydraulic cylinder. a Lower the blade gradually to the ground. Just after the blade reaches the ground, set the blade lever in the FLOAT position. 2. Set the safety lock lever in the FREE position and operate the blade lever and ripper lever for- ward, backward, to the right, and to the left. a After the levers are operated 2 – 3 times, the residual pressure in the accumulator is fully released. 2. Turn the starting switch OFF and quickly operate the blade lever and ripper lever forward, back- ward, to the right, and to the left.

a After turning the starting switch OFF, operate the levers quickly until the engine stops com- plately. 3. Run the engine at low idling for about 5 seconds, and then stop it. 4. Repeat steps 2 and 3 by 2 – 3 times. was relieved at the stroke end, perform either of the following operations.> Start the engine again and perform steps 1 and 2 (This operation is recommended). Wait for 5 – 10 minutes after stopping the engine, and then perform following steps 3 and 4. 3. Loosen the hydraulic tank cap gradually to release the residual pressure in the tank. 4.

Apply cloths to the joint of the cylinder piping and loosen the sleeve nut gradually to release the residual pressure, while shaking the hose slowly. a Check that the residual pressure is released and oil does not spout out any more, and then disconnect the piping. D85EX-15 20-153 (4)