TESTING AND ADJUSTING TESTING AND ADJUSTING OF OPERATOR’S CAB TESTING AND ADJUSTING OF OPERATOR’S CAB a [a] side: Inside of cab [Pressurized] [b] side: Out of cab [Atmospheric pressure] Check after installing cab assembly 1. Measuring pressure in cab Criterion: Measured value X 78.5 Pa {8 mmH 2 O} Engine speed: High idling Fan speed: 100% mode (Refer to user adjustment mode on monitor panel) Air conditioner fan switch: High Air conditionerFresh/Recirculation switch: Fresh air position a If the measured value is lower than the stan- dard value, check the seals of the holes for wiring harnesses and optional parts in the cab. 2. Check of searing performance 1) Close the all openings of the cab.
2) Splash water around the hatched part of the cab at the rate of about 19 /min for 10 min- utes. At this time, it is not necessary to splash pressurized water. 3) Splash water horizontally from a hose over sealing surface (4). 4) Check around the dashboard carefully. a If water leaks, caulk the leaking part and check again. 1) A simple method of measuring the internal pressure is as follows. i) Prepare a transparent vinyl hose. Inside diameter: 6 mm, Length: 3,000 mm ii) Secure the inside end of the hose to the top of the back seat with a tape. iii) Remove bolt (1) under the left console box.
Pass the other end of the hose through the bolt hole and take it out of inspection cover (2) on the left side of the cab. iv) Seal the hole of bolt (1) with tape (3). v) Pour water in the hose up to about half, then bent the hose to U -shape. vi) Set the water level in the vinyl hose out of the cab to that in the cab. vii) Run the engine at high idling and mea- sure water level difference " c ". (Value " c ": Pa {mmH 2 O}) 20-160 D85EX-15 (5)