Komatsu — TESTING AND ADJUSTING OF OPERATOR'S CAB

TESTING AND ADJUSTING TESTING AND ADJUSTING OF OPERATOR’S CAB 3. Testing door lock Close the door and check the relationship between the operator’s cab and door. If there is any fault, repair it. 1) Check of condition i) Check the installed height to damper rub- ber (1). (Check both sides, 2 pieces on each.) Stick adhesive tape , etc. to the contact face of damper rubber (1) and open and close the door 2 – 3 times. Then, check the contact face of adhesive tape against the oper- ator’s cab. Normal: When the door is closed, the damper rubber comes in contact lightly. Abnormal:

When the door is closed, the damper rubber does not come in contact or comes in contact so strongly that adhesive tape is removed. 2) Adjusting i) Adjusting height of damper rubber Loosen the mounting bolts of dumper rubber (1). a You can remove or install the shims without removing the mounting bolts. Increase or decrease of shims (5) under damper rubber (1) to adjust the height of damper rubber (1) prop- erly. ii) Check the relationship between the door notch and striker (on both sides). Close door (2) and check the engag- ing condition of latch (3) and striker (4). Normal: Error of " a " must be 0.5 mm or less.

a Check deviation a of latch cen- ter y and striker center x from each other from the direction of A . D85EX-15 20-161 (5)