Komatsu — SPECIAL FUNCTIONS OF MONITOR PANEL (EMMS)

TESTING AND ADJUSTING SPECIAL FUNCTIONS OF MONITOR PANEL (EMMS) Operation and display in operator mode (Outline) a In this section, only the outline of the operation mode is described. For the details of the con- tents and operation method of each function and mode, see Operation Manual. Normal display mode (Default) The monitor panel displays the following information normally. Gear speed display section (1): Front side: Travel direction (P · N · F · R) Rear side: Gear speed (1 · 2 · 3) Graphics: Engine speed Multi-information section (2): a Information is displayed in 2 lines of 16 charac- ters each. Front side:

Gear shift mode (F1-R1 · F1-R2 · F2-R2) (Displayed when preset mode is set) Rear side: Service meter (Unit: 0.1h) Each time the information switch is set to the right or left, the service meter and engine speed are displayed alternately. 1. Maintenance mode (1-OIL, FILTER MAINTENANCE MODE) In this mode, the time up to the next replacement of oils and filters is displayed on the multi-infor- mation section (2) and reset after the replace- ment. a Gear speed display section (1) keeps dis- playing normally. No. Maintenance item The items marked with a are displayed but not used for this machine.

20-166 D85EX-15 (1) 01 02 Engine oil Engine oil filter 03 Fuel filter 04 Hydraulic oil filter 05 Corrosion resistor 06 Bypass filtera 07 Damper oil 08 Final drive oil 09 Hydraulic oil 10 Power train oil 11 Power train oil filter 12 HSS charge filter (HSS specification)a