Komatsu — SPECIAL FUNCTIONS OF MONITOR PANEL (EMMS)

TESTING AND ADJUSTING SPECIAL FUNCTIONS OF MONITOR PANEL (EMMS) 2. Pm clinic auxiliary mode (2-PM CLINIC MODE) In this mode, the condition of the machine is dis- played on multi-information section (2) as an auxiliary function of the periodic diagnoses such as the Pm clinic, even if any measuring instru- ment is not connected. a Gear speed display section (1) keeps dis- playing normally. No. Pm clinic auxiliary item 3. Error code display mode (3-ERROR CODE DISPLAY MODE) In this mode, the contents of each fault in the machine are displayed by a 6-character error code on the multi-information section (2).

When the user or the operator needs to be noti- fied of the error code of each fault, this mode is applied. a Gear speed display section (1) keeps dis- playing normally. a When a serviceman needs to check the error codes for troubleshooting, the Electric sys- tem error code display mode and the Mechanical system error code display mode should be used for more detailed informa- tion. a Method of checking error code: Turn buzzer cancel switch (4) to the [ ] position on the screen shown at right, and the all error codes detected currently are dis- played at the interval of about 2 seconds.

(To finish displaying, turn the buzzer cancel switch to the [ ] position.) a For the error codes list, see TROUBLE- SHOOTING. D85EX-15 20-167 (1) 01 02 Engine speed Boost pressure 03 Work equipment pressure 04 Battery voltage