Komatsu — SPECIAL FUNCTIONS OF MONITOR PANEL (EMMS)

TESTING AND ADJUSTING SPECIAL FUNCTIONS OF MONITOR PANEL (EMMS) a Flashing and lighting of error code Flashing: Code is being output currently. Lighting: Code is not being output cur- rently. a Condition for detecting and keeping error code If a error code of any item other than communication is output, it keeps flash- ing until the starting switch is turned off. After the starting switch is turn on or the engine is started again, the error code keeps lighting until the same fault is detected. A error code of communication starts lighting when the fault is solved, even if the starting switch is turned off. 4) Operation to take when multiple codes are recorded.

When multiple codes are recorded, they can be displayed one by one by operating infor- mation switch (5). [ > ]: Next code [ a The error codes are displayed from the oldest one in order of length of time after they were output. 5) Method of deleting error code The mechanical system error codes cannot be deleted. D85EX-15 20-177 (1)