TESTING AND ADJUSTING SPECIAL FUNCTIONS OF MONITOR PANEL (EMMS) [ 7 ] 0009: Pitch angle sensor initial set This code is used to adjust the zero point and installation error of the pitch angle sensor. The deviation from the standard neutral position is displayed by voltage on the lower line (Display range: 2500 – 2500). Adjustment method: Stop the machine on level ground, then set buzzer cancel switch (4) in the [ ] position and check that the caution buzzer sounds. a Even after adjustment, the display of the lower line does not change. a Even if this code is turned off, the setting is effective. [ 8 ] 0010:
Fan 70% speed mode This code forcedly sets the rpm of cooling fan at approximately 70% of the maximum speed. The lower part displays data for adjustment. Instructions for use: The function is enabled with this code displayed to control the rpm of cooling fan to approximately 70% of the maximum speed. a Ending this code disables the function. 20-184 D85EX-15 (1)