TESTING AND ADJUSTING SPECIAL FUNCTIONS OF MONITOR PANEL (EMMS) [ 5 ] 0007: Engine deceleration-cut mode This code is used to stop the auto-deceleration function of the engine and check the high idling speed of the engine singly. The engine speed is displayed on the lower line (Display range: 0 – 3000). Using method: While this code is displayed, its function is turned on and the auto-deceleration function is turned off. a If this code is turned off, its function is turned off. [ 6 ] 0008:
Common rail reduced cylinder mode a When the engine common rail system seems to be faulty, this code is used to stop injecting fuel into 1 or more cylinders (reduce the number of effective cylinders) while the engine is running and find out a faulty cylinder from the change of the engine speed. a Since a fault is detected by the difference of the engine speed in the reduced cylinder mode oper- ation from that in the normal mode operation, use this function while the engine is running. The engine speed is displayed on the lower line (Display range: 0 – 3000). Using method:
Select the cylinders to be turned off for the reduced cylinder mode operation by operating information switch (5) and buzzer cancel switch (4). Use this method to turn on the selected cylinders again, too. [ > ]: Move cursor to right. [ Move cursor to left. [ ]: Execute or stop reduced cylinder mode operation. a The figure at right is an example that No. 2 cylinder is turned off for reduced cylinder mode operation and turned on again (The cylinder No. lamp is turned off in the reduced cylinder mode operation and on in the nor- mal mode operation). a Only one or more cylinders can be turned off for the reduced cylinder mode operation. a If this code is turned off, its function is turned off.
D85EX-15 20-183 (1)