TESTING AND ADJUSTING SPECIAL FUNCTIONS OF MONITOR PANEL (EMMS) [ 3 ] 0004: Machine specification set This code is used to have the machine specifica- tion recognized by the controllers which com- pose the system. The machine specification code is displayed on the lower line. Adjustment method: a Since this code is reset when “Steering and transmission controller specification set” is executed, adjust it after that. 1) Select the code of the machine specification by setting shift up switch (5) in the [ > ] posi- tion. 2) Set buzzer cancel switch (4) in the [ ] posi- tion and check that the caution buzzer sounds.
If the machine specification is different from the setting in the controller, the machine may move abnormally or an error may be made. Accordingly, be sure to match the setting to the machine specification. a Even if this code is turned off, the setting is effective. [ 4 ] 0005: Brake potentiometer zero point adjust- ment This code is used to adjust the zero point of the potentiometer of the brake pedal. The deviation from the standard is displayed by voltage on the lower line (Display range: 2500 – 2500). Adjustment method: With the brake pedal released, set buzzer cancel switch (4) in the [ ] position and check that the caution buzzer sounds.
a Even if the neutral position of the brake pedal is adjusted, the display of the lower line does not change. a Even if this code is turned off, the setting is effective. a This code is not for adjustment of the braking performance, etc. 20-182 D85EX-15 (1) No. Specificatio 00 Standard specification 08 – 80 Standard cold district sp 88 –