Komatsu — SPECIAL FUNCTIONS OF MONITOR PANEL (EMMS)

TESTING AND ADJUSTING SPECIAL FUNCTIONS OF MONITOR PANEL (EMMS) 9. Load memory display mode (9-LOAD MEMORY DISPLAY MODE) In this mode, you can check the load on the machine, forward odometer, and reverse odome- ter. 1) Selecting and executing mode i) Select “Load memory display mode” on the mode selection screen. a If the mode is selected, code (Ld) is displayed on gear speed display sec- tion (1) and the title is displayed on multi-information section (2). ii) Display the adjustment code input screen by operating buzzer cancel switch (4). [ ]: Execute mode. 2) Changing information screen Change the information screen by operating information switch (5). [ > ]: Next screen.

[ 3) Display of 1,000rpm service meter (01) This code is used to display the service meter which integrates the operation hours only while the engine speed is higher than 1,000rpm. a The data cannot be reset. D85EX-15 20-189 (1) No. Displayed information 01 1,000rpm service meter 02 Forward odometer 03 Reverse odometer