TESTING AND ADJUSTING SPECIAL FUNCTIONS OF MONITOR PANEL (EMMS) 10. Real-time monitoring mode (10-REAL TIME MONITORING MODE) In this mode, the speeds, oil pressures, oil tem- peratures, currents, voltages, etc. can be moni- tored by using the signals from sensors, switches, and solenoids installed various parts of the machine. a This mode is used to monitor 1 item. When monitoring 2 items simultaneously, use the “Dual display monitoring mode”. 1) Selecting and executing mode i) Select “Real-time monitoring mode” on the mode selection screen. a If the mode is selected, code (5R) is displayed on gear speed display sec- tion (1) and the title is displayed on multi-information section (2).
ii) Display the monitoring code input screen by operating buzzer cancel switch (4). [ ]: Decide selection. 2) Selecting and entering monitored items i) On the code input screen, input the 5- digit code of the item to be monitored by operating information switch (5), shift-up switch (6), and shift-down switch (7). [ > ]: Move cursor to right. [ Move cursor to left. [UP]: Increase number. [DOWN]: Decrease number. iii) After inputting the code, display the monitor- ing screen by operating buzzer cancel switch (4). [ ]: Enter input code. a If the input code is correct, the monitoring screen shown at right appears. D85EX-15 20-191 (1)