TESTING AND ADJUSTING SPECIAL FUNCTIONS OF MONITOR PANEL (EMMS) The numbers marked with a can be displayed in order by setting the information switch in the ">" or " D85EX-15 20-195 (1) No.
Code Monitored item Unit Display range 47 40905 T/M-SW1 Transmission-related controller input signal 1 Bit (See detailed information) 48 40906 T/M-SW2 Transmission-related controller input signal 2 Bit (See detailed information) 49 40909 T/M SOL.2 Transmission-related controller output signal Bit (See detailed information) 50 40910 S/T-SW1 Steering-related controller input signal 1 Bit (See detailed information) 51 40911 S/T-SW2 Steering-related controller input signal 2 Bit (See detailed information) 52 40913 S/T-SW5 Steering-related controller input signal 5 Bit (See detailed information) 53 40914 S/T SOL.1 Output signal of steering controller Bit (See detailed information) *54 50000 DESEL PEDAL Deceleration ratio % 0 – 100 *55 50100 SSC 3rd throttle % 0 – 100 56 50101 SSC ORDER 3rd throttle command voltage mV 0 – 5000 *57 50200 T/M LEVER 1 Voltage of forward-reverse potentiometer 1 mV 0 – 5000 *58 50201 T/M LEVER 2 Voltage of forward-reverse potentiometer 2 mV 0 – 5000 *59 50300 S/T LEVER 1 Voltage of steering potentiometer 1 mV 0 – 5000 *60 50301 S/T LEVER 2 Voltage of steering potentiometer 2 mV 0 – 5000 *61 50400 BRAKE PEDL Voltage of brake potentiometer mV 0 – 5000 *62 50600 HSS L.H.F Output FB current of left HSS solenoid mA 0 – 1000 *63 50601 HSS R.H.F Output FB current of right HSS solenoid mA 0 – 1000 64 50602 HSS L.H.O Output command current of left HSS solenoid mA 0 – 1000 65 50603 HSS R.H.O Output command current of right HSS solenoid mA 0 – 1000 *66 50900 N-SAFETY Drive current of neutral safety relay mV 0 – 30000 67 51000 SSC ORDER 3rd throttle command speed rpm 0 – 3000 *68 60000 TRACTION Traction force (Theoretical value) W 0 – 0 69 60100 BODY ANGLE Machine pitch angle sensor voltage mV 0 – 5000 70 60600 BR HOLD Drive voltage of battery relay mV 0 – 30000 71 60700 S/T MODE Steering state code Character 72 60800 FILL MODE Variable for setting fill condition Character 73 60909 MOD.
MODE Setting of modulation condition Character 74 70000 CHG. P. MODE Variable for setting condition of gear shift point Character 75 70400 BACK ALARM Drive voltage of back-up alarm relay mV 0 – 30000 76 70500 Regulation Reguration speed rpm 0 – 2200 77 70700 HYD. PUMP 1 Work equipment oil pressure MPa 0 – 50 78 70701 HYD. PUMP 1 Voltage of work equipment oil pressure sensor mV 0 – 5000