Komatsu — SPECIAL FUNCTIONS OF MONITOR PANEL (EMMS)

TESTING AND ADJUSTING SPECIAL FUNCTIONS OF MONITOR PANEL (EMMS) Detailed information on bit display codes Examples of display of bit information a The display position of the bit information in the “Real-time monitoring mode (Display of only 1 item)” is different from that in the “Dual display monitoring mode (Simultaneous display of 2 items)”. a The bit information is displayed by [ ] for OFF and [o] for ON in the places . a The state of each item shown below is the condi- tion for turning on the bit. 31520: Input state of transmission related fill switch : Forward clutch fill switch: ON : Reverse clutch fill switch: ON : 1st clutch fill switch: ON : 2nd clutch fill switch: ON :

3rd clutch fill switch: ON : (Unused) : (Unused) : (Unused) 40900: Engine controller input signal 1 : Starting switch signal C: Input : (Unused) : (Unused) : Low engine oil pressure switch: ON : High engine oil pressure switch: ON : (Unused) : (Unused) : Model selection signal 1: ON 40901: Engine controller input signal 2 : Model selection signal 2: ON : Model selection signal 3: ON : (Unused) : (Unused) : N-signal 1: ON : N-signal 2: ON : (Unused) : (Unused) 20-196 D85EX-15 (1)