TROUBLESHOOTING CLASSIFICATION AND PROCEDURES OF TROUBLESHOOTING CLASSIFICATION AND PROCEDURES OF TROUBLESHOOTING Classification of Troubleshooting Troubleshooting Procedures When any phenomenon supposed to be a failure appeared on the machine, select a Troubleshooting No. according to the procedures below and proceed to the text of the relevant troubleshooting: 1. Troubleshooting Procedures when any action code is displayed on the monitor panel: When an action code is displayed on the monitor panel, display a error code in the error code display mode (electrical system, mechanical system) on the monitor display (EMMS).
Execute a troubleshooting of the relevant [Error Code] in accordance with the displayed error code. a Since a error code flashes when a problem was detected, the failure has not always been corrected even if it lights when the starting switch is set to ON. (For some codes, problems can be detected only when the starting switch is set to ON.) a When a error code has been recorded, be sure to reproduce the code and check if the problem of the code has still remained or has already been corrected. (For the reproducing method, refer to the trouble- shooting of the error code.) 2. Troubleshooting Procedures when error codes have been recorded:
When no action code is displayed on the monitor panel, check a error code in the error code display mode (electrical system, mechanical system) on the monitor panel (EMMS). When error codes have been recorded, execute a troubleshooting of the relevant [Error Code] in accor- dance with the error code. a Since a error code flashes when a problem was detected, the failure has not always been corrected even if it lights when the starting switch is set to ON.
(For some codes, problems can be detected only when the starting switch is set to ON.) a When a error code has been recorded, be sure to reproduce the code and check if the problem of the code has still remained or has already been corrected. (For the reproducing method, refer to the trouble- shooting of the error code.) 3. Troubleshooting Procedures when no action code is displayed and error codes have not been recorded: When error codes have not been recorded in the monitor panel (EMMS), a failure that the machine cannot diagnose by itself is supposed to have occurred in the electrical system or the hydraulic/mechanical system.
In this case, check again a phenomenon supposed to be a failure and select the relevant phenomenon out of the table of “Phenomena supposed to be Failures and Troubleshooting No.” Then, execute the trouble- shooting in the [E Mode] , [H Mode] or [S Mode] related to the phenomenon. D85EX-15 20-313 (1) Mode Explanation Error code Troubleshooting when a service code is displayed E Mode Troubleshooting of the electrical system H Mode Troubleshooting of the hydraulic and mechanical systems S Mode Troubleshooting of the engine body