Komatsu — CLASSIFICATION AND PROCEDURES OF TROUBLESHOOTING

TROUBLESHOOTING CLASSIFICATION AND PROCEDURES OF TROUBLESHOOTING D85EX-15 20-315 (1) No. Phenomenon suppose to be Failure Troubleshooting Error Code E Mode H Mode S Mode Phenomenon related to monitor panel (Operator mode: Normal screen) 40 When the starting switch is set to ON, no light on the monitor panel comes on. E-3 41 When the starting switch is set to ON, all the lights on the monitor panel do not go out. E-4 42 When the starting switch is set to ON, the radiator water level caution flashes. E-5 43 While the engine is operating, the caution items flash. E-6 44 While the engine is operating, the emergency warning items flash.

E-7 45 While the preheater is operating, the preheating pilot lamp does not come on. E-8 46 Indication of the engine water temperature gauge is abnormal. E-9 47 Indication of the power train oil temperature gauge is abnormal. E-10 48 Indication of the hydraulic oil temperature gauge is abnormal. E-11 49 Indication of the fuel gauge is abnormal. E-12 50 Indications of gear speed and engine speed are abnormal. E-13 51 Indication of the preset mode service meter is abnormal. E-14 52 The warning lamp does not flash or does not go out. E-15 53 The alarm buzzer does not sound or does not stop. E-16 54 Auto shift down is not possible or is not released.

E-17 55 The buzzer cancel switch does not work. E-18 56 The information switch does not work. E-19 57 The manual mode does not be operated or cancelled. E-20 Phenomenon related to monitor panel (Service mode: Special function screen) 58 The monitor panel cannot be set in the service mode. E-21 Others 59 The back-up alarm does not sound. E-22 60 The head lamp, rear lamp, and ripper point lamp on the panel do not come on. E-23 61 The wiper malfunctions. E-24 62 Washing water does not come out. E-25 63 The air conditioner does not operate. E-26