Komatsu — ERROR CODE [15SBL1] (REVERSE CLUTCH:SEE THE LIST.(L1))

TROUBLESHOOTING ERROR CODE 15SBL1 ERROR CODE 15SBL1 (REVERSE CLUTCH: SEE THE LIST. (L1)) Circuit diagram related to transmission reverse clutch ECM 20-410 D85EX-15 (1) Action co de Error code Controller code R Trouble ( everse clutch: See the list. (L1) Steering and transmission controller system) CALL E0 3 15SBL1 Steering and transmission Contents trouble of • The fill switch signal is not set off at output stop of the transmission reverse clutch solenoid circuit. Action o controlle • Flashes caution lamp and turns on caution buzzer. f • Decides that engine speed is neutral (N) at forward operation. r • Limits operation of engine and transmission.

Problem t appears machin hat • Once machine is stopped, engine speed is limited to medium (half). on • Once machine is stopped, running is limited to R1. e Related informati • The input state (ON/OFF) from the reverse clutch fill switch can be checked in monitoring mode. (Code 31520: Transmission fill switch input state) on • Method of reproducing error code:

Engine start + Forward running Possible ca and standar value in nor state Cause Defective reverse clutch fill 1 switch (Internal short) Defective harness ground- uses 2 ing (Contact with ground cir- d cuit) mal Defective steering and 3 transmission controller Defective hydraulic pres- 4 sure system i Standard value in normal state/Remarks on troubleshooting Defective reverse clutch fill switch (Internal short) aPrepare with starting switch OFF, then start the engine for trouble- shooting. FRT (male) PCCS lever Resistance Between (1) – chassis ground N Min. 1Mz R (Reverse) Max.

1z Defective harness ground- ing (Contact with ground cir- cuit) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between STC2 (female) (25) – FFT (female) (1) with chassis ground Resistance Max. 1Mz Defective steering and transmission controller aPrepare with starting switch OFF, then start the engine for trouble- shooting. STC2 PCCS lever Voltage Between (24) and (25) – chassis ground N 20 – 30V R (Reverse) Max. 1V Defective hydraulic pres- sure system i When no fault is detected in the electric system, the hydraulic pressure system is assumed to be abnormal. Carry out the related troubleshoot- ng (H mode).