Komatsu — ERROR CODE [15SGL1] (3RD CLUTCH:SEE THE LIST.(L1))

TROUBLESHOOTING ERROR CODE 15SGL1 ERROR CODE 15SGL1 (3RD CLUTCH: SEE THE LIST. (L1)) Circuit diagram related to transmission 3rd clutch ECMV 20-416 D85EX-15 (1) Action cod e Error code C ontroller code 3 Trouble (S rd clutch: See the list. (L1) teering and transmission controller system) CALL E0 3 15SGL1 Steering and transmission Contents trouble of • The fill switch signal is not set off at output stop of the transmission 3rd clutch solenoid circuit. Action of controller • Flashes caution lamp and turns on caution buzzer. • Limits operation of engine and transmission. Problem th appears o machine at • The auto shift down function does not operate.

n • Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, running is limited to F3 and R3. Related informatio • The input state (ON/OFF) from the 3rd clutch fill switch can be checked in monitoring mode. (Code 31520: Transmission fill switch input state) n • Method of reproducing error code:

Engine start + Neutral running Possible cau and standard value in norm state Cause Defective 3rd clutch fill 1 switch (Internal short) Defective harness ground- ses 2 ing (Contact with ground cir- cuit) al Defective steering and 3 transmission controller Defective hydraulic pres- 4 sure system Standard value in normal state/Remarks on troubleshooting Defective 3rd clutch fill switch (Internal short) aPrepare with starting switch OFF, then start the engine for trouble- shooting. F3T (male) PCCS lever Resistance Between (1) – chassis ground Other than F3/R3 Min. 1Mz F3·R3 Max.

1z Defective harness ground- ing (Contact with ground cir- cuit) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between STC3 (female) (39) F3T (female) (1) with chassis ground – Resistance Max. 1Mz Defective steering and transmission controller aPrepare with starting switch OFF, then start the engine for trouble- shooting. STC3 PCCS lever Voltage Between (39) – chassis ground Other than F3/R3 20 – 30V F3·R3 Max. 1V Defective hydraulic pres- sure system When no fault is detected in the electric system, the hydraulic pressure system is assumed to be abnormal. Carry out the related troubleshoot- ing (H mode).