Komatsu — ERROR CODE [AD00L2] (COMMON RAIL:SEE THE LIST.(L2))

TROUBLESHOOTING ERROR CODE AB00MA, ERROR CODE AD00L2 ERROR CODE AB00MA (ALTERNATOR: MALFUNCTION (MA)) ERROR CODE AD00L2 (COMMON RAIL: SEE THE LIST. (L2)) D85EX-15 20-419 (1) Action code Error code Controller code Trouble Alternator: Malfunction (MA) (Mechanical system) — AB00MA — Contents of trouble • During rotation of engine, charge level caution lamp flashes. Action of controller Problem that appears on machine • If machine is operated as it is, battery may be discharged. Related information • Method of reproducing error code: Start engine.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective battery charge (When system is in normal state) It is suspected that problem causing defective battery charge is occur- ring at present or occurred in past. Investigate cause and damage con- dition, and correct it. 2 Defective charge level cau- tion lamp system Carry out troubleshooting of charge level caution lamp system in ac- cordance with “During running of engine, emergency caution item flashes” in E mode. Action code Error code Controller code Trouble Common rail: See the list.

(L2) (Engine controller system) E02 AD00L2 ENG Contents of trouble • The fuel pressure of common rail became high (level 1). Action of controller • Flashes caution lamp and turns on caution buzzer. • Limits output for operation. Problem that appears on machine • Engine output reduces. Related information • The fuel state (fuel pressure) of common rail can be checked in monitoring mode. (Code 36400: Common rail pressure) • Method of reproducing error code: Engine start Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective related system Check the displayed error code.

If another code is displayed, first carry out troubleshooting for the code. 2 Inappropriate fuel The fuel used may be inappropriate; directly check it. 3 Defective electric system of common rail pressure sen- sor Carry out troubleshooting for error code [DH40KX]. 4 Defective mechanical sys- tem of common rail pres- sure sensor The common rail pressure sensor is assumed to be defective mechan- ically; directly check it. 5 Defective overflow valve The overflow valve may cause spring damage, sheet abrasion, or ball fixing; directly check it. 6 Clogged overflow pipe The overflow pipe is assumed to be clogged; directly check it.

7 Defective pressure limiter The pressure limiter is assumed to be defective mechanically; directly check it.