Komatsu — ERROR CODE [AD11KB] (FUEL SUPPLY PUMP SOLENOID 1:SHORT CIRCUIT (KB))

TROUBLESHOOTING ERROR CODE AD11KB ERROR CODE AD11KB (FUEL SUPPLY PUMP SOLENOID 1: SHORT CIRCUIT (KB)) Circuit diagram related to fuel supply pump solenoid 1 D85EX-15 20-425 (1) Action code Error code Controller code Trouble Fuel supply pump solenoid 1: Short circuit (KB) (Engine controller system) CALL E03 AD11KB ENG Contents of trouble • Overcurrent flowed in fuel supply pump solenoid 1 (PCV1) circuit. Action of controller • Flashes caution lamp and turns on caution buzzer. • Limits operation of engine and transmission. • Stops output to fuel supply pump solenoid 1 circuit. Problem that appears on machine • Once machine is stopped, engine speed is limited to medium (half).

• Once machine is stopped, travel is limited to F1 and R1. • When code [AD51KA] and [AD51KB] appear at the same time, engine stops. Related information • For troubleshooting of fuel supply pump solenoid 1, special adaptor (799-601-9430) is required. • Method of reproducing error code: Start engine.

Possible causes and standard value in normal state Cause Defective fuel supply pump 1 solenoid 1 (Internal short circuit) Short circuit with chassis 2 ground in wiring harness (Contact with ground circuit) Hot short circuit in wiring 3 harness (Contact with 24V circuit) 4 Defective engine controller Standard value in normal state/Remarks on troubleshooting Defective fuel supply pump solenoid 1 (Internal short circuit) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. PCV1 (male) Resistance Between (1) – (2) 2.3 – 5.3z Between (1) – chassis ground Min.

1Mz Short circuit with chassis ground in wiring harness (Contact with ground circuit) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between EGC3 (female) (12) – PCV1 (female) (1) with chassis ground Resistance Max. 1Mz Hot short circuit in wiring harness (Contact with 24V circuit) aPrepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Short circuit of wiring harness between EGC3 (female) (12) – PCV1 (female) (1) with chassis ground Voltage Max. 1V Short circuit of wiring harness between EGC3 (female) (22) – PCV1 (female) (2) with chassis ground Voltage Max.

1V Defective engine controller aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. EGC3 (male) Resistance Between (12) – (22) 2.3 – 5.3z Between (12) (22) – chassis ground Min. 1Mz