Komatsu — ERROR CODE [ADB1KA] (NO.2 INJECTOR SOLENOID:DISCONNECTION IN WIRING(KA))

TROUBLESHOOTING ERROR CODE ADB1KA ERROR CODE ADB1KA (NO.2 INJECTOR SOLENOID: DISCONNECTION IN WIRING (KA)) Circuit diagram related to No.2 injector solenoid D85EX-15 20-431 (1) Action code Error code Controller code Trouble No.2 injector solenoid: Disconnection in wiring (KA) (Engine controller system) E02 ADB1KA ENG Contents of trouble • Disconnection in wiring occurred in the No.2 injector solenoid (TWV#2) circuit. Action of controller • Flashes caution lamp and turns on caution buzzer. • Stops output to the No.2 injector solenoid circuit. Problem tha appears on machine t • Engine output reduces. Related information • Method of reproducing error code:

Engine start Possible caus and standard value in norma state Cause Defective No.2 injector sole 1 noid (Internal disconnection in wiring) es Disconnection in wiring har- ness (Disconnection in wir- l 2 ing or defective contact in connector) 3 Defective engine controller Standard value in normal state/Remarks on troubleshooting aPrepare with starting switch OFF, then carry out troubleshooting - without turning starting switch ON. CN2 (male) Resistance Between (1) and (2) 0.4 – 1.1z Resistance 0.4 – 1.1z aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between EGC3 (female) (6) – Resistance Max.

1z CN2 (female) (1) Wiring harness between EGC3 (female) (16) – Resistance Max. 1z CN2 (female) (2) Resistance Max. 1z Resistance Max. 1z aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. EGC3 (male) Resistance Between (6) and (16) 0.4 – 1.1z Resistance 0.4 – 1.1z