Komatsu — ERROR CODE [ADAZKB] (NO.1.2,AND 3 INJECTOR SOLENOIDS:SHORT(KB))

TROUBLESHOOTING ERROR CODE ADAZKB Circuit diagram related to No.1, 2, and 3 injector solenoids 20-430 D85EX-15 (1) Possible cau and standar value in nor state Cause ses d Defective harness hot short mal 5 (Contact with 24V circuit) Standard value in normal state/Remarks on troubleshooting Defective harness hot short (Contact with 24V circuit) aPrepare with starting switch OFF, then turn starting switch ON for troubleshooting. Wiring harness between EGC3 (female) (14) CN1 (female) (1) with chassis ground – Voltage Max. 1V Wiring harness between EGC3 (female) (24) CN1 (female) (2) with chassis ground – Voltage Max.

1V Wiring harness between EGC3 (female) (6) CN2 (female) (1) with chassis ground – Voltage Max. 1V Wiring harness between EGC3 (female) (16) CN2 (female) (2) with chassis ground – Voltage Max. 1V Wiring harness between EGC3 (female) (5) CN3 (female) (1) with chassis ground – Voltage Max. 1V Wiring harness between EGC3 (female) (15) CN3 (female) (2) with chassis ground – Voltage Max. 1V