TROUBLESHOOTING ERROR CODE D110KA ERROR CODE D110KA (BATTERY RELAY: DISCONNECTION (KA)) Circuit diagram related to battery relay D85EX-15 20-441 (1) Action code Error code Controller cod e Batte Trouble (Stee ry relay: Disconnection (KA) ring and transmission controller system) — D110KA Steering and transmission Contents of trouble • Current does not flow when outputting it to battery relay circuit. Action of controller • Stops output to battery relay circuit. Problem tha appears on machine t • Problem may occur in data writing to ROM (nonvolatile storage) of each controller. Related information • Output state (voltage) to battery relay can be checked in monitoring mode. (Code 60600:
Battery relay drive voltage) • Method of reproducing error code: Switch starting switch from ON to OFF. Possible caus and standard value in norma state Cause Defective battery relay (In- 1 ternal disconnection) Disconnection in wiring har- ness (Disconnection in wir- es 2 ing or defective contact in connector) l Hot short circuit in wiring 3 harness (Contact with 24V circuit) Defective steering and 4 transmission controller Standard value in normal state/Remarks on troubleshooting Defective battery relay (In- ternal disconnection) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.
Battery relay Continuity Between terminals SW – ground terminal Continue Disconnection in wiring har- ness (Disconnection in wir- ing or defective contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between STC3 (female) (4) – battery relay SW terminal Resistanc e Max. 1z Wiring harness between battery relay ground terminal – chassis ground Resistanc e Max. 1z Hot short circuit in wiring harness (Contact with 24V circuit) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.
Short circuit of wiring harness between STC3 (female) (4) – battery relay terminal SW – S13 (female) (10) with chassis ground Voltage Max. 1V Defective steering and transmission controller aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. STC3 (female) Continuity Between (4) – chassis ground Continue