Komatsu — ERROR CODE [D110KB] (BATTERY RELAY:SHORT CIRCUIT(KB))

TROUBLESHOOTING ERROR CODE D110KB ERROR CODE D110KB (BATTERY RELAY: SHORT CIRCUIT (KB)) Circuit diagram related to battery relay 20-442 D85EX-15 (1) Action code Error code Controller cod e Batte Trouble (Stee ry relay: Short circuit (KB) ring and transmission controller system) — D110KB Steering and transmission Contents of trouble • Abnormal current flowed to battery relay circuit when outputting it. Action of controller • Stops output to battery relay circuit. Problem tha appears on machine t • Problem may occur in data writing to ROM (nonvolatile storage) of each controller. Related information • Output state (voltage) to battery relay can be checked in monitoring mode. (Code 60600:

Battery relay drive voltage) • Method of reproducing error code: Switch starting switch from ON to OFF. Possible caus and standard value in norma state Cause Defective battery relay 1 (Internal short circuit) es l Short circuit with chassis 2 ground in wiring harness (Contact with ground circuit) Defective steering and 3 transmission controller Standard value in normal state/Remarks on troubleshooting Defective battery relay (Internal short circuit) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Battery relay Continuity/resistance Between terminals SW – ground terminal Continue Between terminal SW – chassis ground Min.

1Mz Short circuit with chassis ground in wiring harness (Contact with ground circuit) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Short circuit of wiring harness between STC3 (female) (4) – battery relay terminal SW – S13 (female) (10) with chassis ground Resistanc Min. e 1Mz Defective steering and transmission controller aPrepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. STC3 Starting switch Voltage Between (4) – chassis ground ON 20 – 30V