TROUBLESHOOTING ERROR CODE D130KB ERROR CODE D130KB (NEUTRAL SAFETY RELAY: SHORT CIRCUIT (KB)) Circuit diagram related to neutral safety relay D85EX-15 20-445 (1) Action code Error code Controller code Steering and D130KB transmission Neut Trouble (Stee ral safety relay: Short circuit (KB) ring and transmission controller system) E02 Contents of trouble • Abnormal current flowed in neutral safety relay circuit at the time of ground output. Action of controller • Flashes caution lamp and turns on caution buzzer. • Stops ground output to neutral safety relay circuit. Problem that appears on machine • Engine does not start.
Related information • Output state (voltage) to neutral safety relay can be checked in monitoring mode. (Code 50900: Neutral safety relay drive voltage) • Method of reproducing error code: Turn starting switch ON and operate parking lever (Free position). aThis error code detects abnormality in primary side (coil side) of neutral safety relay, but not in second- ary side (contact side) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting Defective neutral safety re 1 lay (Internal short circuit) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.
- NSF (male) Resistance Between (1) – (2) 200 – 400z Resistance 200 – 400z Hot short circuit in wiring 2 harness (Contact with 24V circuit) aPrepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Short circuit of wiring harness between STC2 (female) (8) – NSF (female) (2) with chassis Voltage Max. 1V ground 2 Voltage Max. 1V Defective steering and 3 transmission controller aPrepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. STC2 Parking lever Voltage Between (8) – Free position 20 – 30V chassis ground Lock position Max. 1V Parking lever Voltage Free position 20 – 30V Lock position Max. 1V