Komatsu — ERROR CODE [D161KA] (BACK-UP ALARM RELAY: DISCONNECTION (KA))

TROUBLESHOOTING ERROR CODE D161KA ERROR CODE D161KA (BACK-UP ALARM RELAY: DISCONNECTION (KA)) 20-446 D85EX-15 (1) Action code Error code Controller code Trouble Back-up alarm relay: Disconnection (Steering and transmission controller system) E01 D161KA Steering and transmission Contents of trouble • 24V is not generated when ground output of neutral safety relay circuit is interrupted. Action of controller • Stops output to back-up alarm relay circuit. Problem that appears on machine • Back-up alarm is not turned on. Related information • Output state (voltage) to back-up alarm relay can be checked in monitoring mode. (Code 70900:

Back-up alarm relay drive voltage) • Method of reproducing error code: Turn starting switch ON and operate parking lever (Neutral position). aThis error code detects abnormality in primary side (coil side) of back-up alarm relay, but not in second- ary side (contact side) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective fuse FS2-4 If fuse is burnout, circuit probably has short circuit with chassis ground. 2 Defective back-up alarm re- lay (Internal disconnection) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.

BKA (male) Resistance Between (1) – (2) 200 – 400z 3 Defective disconnection in wiring harness (Disconnec- tion in wiring or defective contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between STC2 (female) (18) – BKA (female) (2) Resistance Max. 1z Wiring harness between BKA (female) (1) – FS2-4 outlet port Resistance Max. 1z 4 Short circuit with chassis ground in wiring harness (Contact with ground circuit) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.

Short circuit of wiring harness between STC2 (female) (18) – BKA (female) (2) with chassis ground Resistance Min. 1Mz Short circuit of wiring harness between BKA (female) (1) – FS2-4 outlet port with chassis ground Resistance Min. 1Mz 5 Defective steering and transmission controller aPrepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. STC2 PCCS lever Voltage Between (18) – chassis ground Neutral position 20 – 30V Reverse position Max. 1V