Komatsu — ERROR CODE [DB2AMA] (FUEL INJECTION AMOUNT ADJUSTMENT SWITCH SIGNAL:MALFUNCTION (MA))

TROUBLESHOOTING ERROR CODE DB2AMA ERROR code DB2AMA (FUEL INJECTION AMOUNT ADJUSTMENT SWITCH SIGNAL: MALFUNCTION (MA)) 20-472 D85EX-15 (1) Action code Error code Controller code Trouble Fuel injection amount adjustment switch signal: Malfunction (MA) (Engine controller system) CALL E03 DB2AMA ENG Contents of trouble • Fuel injection amount adjustment switch is not set at correct position. Action of controller • Flashes caution lamp and turns on caution buzzer. • Limits operation of engine and transmission. Problem that appears on machine • Fuel injection amount adjustment setting cannot be changed. • Once machine is stopped, engine speed is limited to medium (half).

• Once machine is stopped, travel is limited to F1 and R1. Related information • Method of reproducing error code: Turn starting switch ON. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective fuel injection amount adjustment switch setting If both fuel injection amount adjustment switches 1 and 2 are set at [F], fuel injection amount adjustment switch setting is defective. 2 Defective engine controller If no problem is found in above cause, it is suspected that engine con- troller is defective.