Komatsu — ERROR CODE [DD11KB] (STARTING SWITCH:SHORT CIRCUIT (KB))

TROUBLESHOOTING ERROR CODE DD11KB ERROR CODE DD11KB (STARTING SWITCH: SHORT CIRCUIT (KB)) Circuit diagram related to starting switch signal C 20-478 D85EX-15 (1) Action code Error code Controller code Trouble Starting switch: Short circuit (KB) (Engine controller system) CALL E04 DD11KB ENG Contents of • trouble Signal C of starting switch is input during running of engine. Action of • controller • Flashes caution lamp and turns on caution buzzer. Limits operation of engine, transmission, and brake. Problem that • appears on • machine • Machine does not operate at all. Once machine is stopped, engine speed is limited to medium (half). Once machine is stopped, it cannot travel any more.

Related • information Method of reproducing error code: Start engine. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting Def 1 sta (Int ective adjustment of rting engine ernal disconnection) aPrepare with starting switch OFF, then carry out troubleshooting with starting switch OFF or ON. Starting switch Starting switch Resistance Between 250 (B) – 280 (C) When OFF/ON Min. 1Mz Hot 2 har circ short circuit in wiring ( ness (Contact with 24V g uit) ( g aPrepare with starting switch OFF, turn starting switch ON and carry out troubleshooting.

Short circuit of wiring harness between EGC1 female) (20) – NSF (female) (5) with chassis round Voltage M ax. 1V Short circuit of wiring harness between NSF female) (3) – starting switch 280 with chassis round Voltage M ax. 1V 3 Def ective engine controller aPrepare with starting switch OFF, turn starting switch ON and carry out troubleshooting. EGC1 Voltage Between (20) – chassis ground Max. 1V