Komatsu — ERROR CODE [DWN2KB] (HSS EPC SOLENOID RIGHT : SHORT CIRCUIT (KB))

TROUBLESHOOTING ERROR CODE DWN2KB ERROR CODE DWN2KB (HSS EPC SOLENOID RIGHT: SHORT CIRCUIT (KB)) Circuit diagram related to HSS EPC solenoid right D85EX-15 20-539 (1) Action code Error code Contro ller code Trouble ng and mission HSS EPC solenoid right: Short circuit (KB) (Steering and transmission controller system) CALL E03 Steeri DWN2KB trans Contents of • trouble When signal was output to HSS EPC solenoid right circuit, abnormal current flowed. • Action of • controller • Flashes caution lamp and turns on caution buzzer. Stops outputting to HSS EPC solenoid right circuit. Limits operation of engine and transmission.

Problem that • appears on • machine Once machine is stopped, engine speed is limited to medium (half). Once machine is stopped, travel is limited to F1 and R1. • Related information • Output (Current) to HSS EPC solenoid right can be checked in monitoring mode. (Code 50601: Right HSS solenoid output current) Method of reproducing service code: Turn starting switch ON and operate PCCS lever (for steering to right). Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting Defective HSS EPC sole- 1 noid right (Internal short cir- cuit) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.

HSB (male) Resistance Between (1) – (2) 10 – 20z Between (1) – chassis ground Min. 1Mz Short circuit with chassis 2 ground in wiring harness (Contact with ground circuit) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Short circuit of wiring harness between STC3 (female) (35) – HSB (female) (1) with chassis ground Resistance Min. 1Mz Short circuit in wiring har- 3 ness (with another wiring harness) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.

Short circuit in wiring harness between STC3 (female) (35) – HSB (female) (1) with wiring harness between STC3 (female) (3) – HSB (female) (2) Resistance Min. 1Mz Defective steering and 4 transmission controller aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. STC3 Resistance Between (35) – (3) 10 – 20z Between (35) – chassis ground Min. 1Mz