Komatsu — ERROR CODE [DWN5KA] (FAN PUMP SOLENOID : DISCONNECTION (KA))

TROUBLESHOOTING ERROR CODE DWN5KA ERROR CODE DWN5KA (FAN PUMP SOLENOID: DISCONNECTION (KA)) Circuit diagram related to fan pump solenoid 20-540 D85EX-15 (1) Action code Error code C ontroller c ode Trouble nd ion Fan pump solenoid: Disconnection (KA) (Steering and transmission controller system) E01 DWN5KA t Steering a ransmiss Contents o trouble f • When signal is output to fan pump solenoid circuit, any current does not flow. Action of controller • Stops outputting to fan pump solenoid circuit. Problem tha appears on machine t • Fan speed is kept at maximum level. Related information • Output (Current) to fan pump solenoid can be checked in monitoring mode. (Code 31623, 31624:

Cooling fan solenoid output current) • Method of reproducing service code: Turn starting switch ON. Possible caus and standard value in norm state Cause Defective fan pump sole- 1 noid (Internal disconnec- tion) Disconnection in wiring ha ness (Disconnection in wir 2 es ing or defective contact in connector) al Short circuit with power 3 source in wiring harness (Contact with 24V circuit) Defective steering and 4 transmission controller Standard value in normal state/Remarks on troubleshooting Defective fan pump sole- noid (Internal disconnec- tion) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.

FAC (male) Resistance Between (1) – (2) 15 – 25z Resistance 15 – 25z Disconnection in wiring ha ness (Disconnection in wir ing or defective contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting r- without turning starting switch ON. - Wiring harness between STC3 (female) (36) – Resistance Max. 1z FAC (female) (1) Wiring harness between STC3 (female) (23) – Resistance Max. 1z FAC (female) (2) Resistance Max. 1z Resistance Max. 1z Short circuit with power source in wiring harness (Contact with 24V circuit) aPrepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting.

Short circuit of wiring harness between STC3 (female) (36) – FAC (female) (1) with chassis Voltage Max. 1V ground Voltage Max. 1V Defective steering and transmission controller aPrepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. STC3 (female) Resistance Between (36) – (23) 15 – 25z Resistance 15 – 25z