TROUBLESHOOTING ERROR CODE DWN5KB ERROR CODE DWN5KB (FAN PUMP SOLENOID: SHORT CIRCUIT (KB)) Circuit diagram related to fan pump solenoid D85EX-15 20-541 (1) Action code Error code C ontroller c ode Trouble nd ion Fan pump solenoid: Short circuit (KB) (Steering and transmission controller system) E01 DWN5KB t Steering a ransmiss Contents o trouble f • When signal was output to fan pump solenoid circuit, abnormal current flowed. Action of controller • Stops outputting to fan pump solenoid circuit. Problem tha appears on machine t • Fan speed is kept at maximum level. Related information • Output (Current) to fan pump solenoid can be checked in monitoring mode. (Code 31623, 31624:
Cooling fan solenoid output current) • Method of reproducing service code: Turn starting switch ON. Possible caus and standard value in norm state Cause Defective fan pump sole- 1 noid (Internal short circuit) Short circuit with chassis 2 ground in wiring harness es (Contact with ground circui al Short circuit in wiring har- 3 ness (with another wiring harness) Defective steering and 4 transmission controller Standard value in normal state/Remarks on troubleshooting Defective fan pump sole- noid (Internal short circuit) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.
FAC (male) Resistance Between (1) – (2) 15 – 25z Between (1) – chassis ground Min. 1Mz Resistance 15 – 25z Min. 1Mz Short circuit with chassis ground in wiring harness (Contact with ground circui aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Short circuit of wiring harness between TMC3 Min. t) (female) (36) – FAC (female) (1) with chassis Resistance 1Mz ground Resistance Min. 1Mz Short circuit in wiring har- ness (with another wiring harness) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Short circuit in wiring harness between TMC3 (female) (36) – FAC (female) (1) with wiring Min.
Resistance harness between TMC3 (female) (23) – FAC 1Mz (female) (2) Resistance Min. 1Mz Defective steering and transmission controller aPrepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. TMC3 Resistance Between (36) – (23) 15 – 25z Between (36) – chassis ground Min. 1Mz Resistance 15 – 25z Min. 1Mz