Komatsu — ERROR CODE [DXA0KA] (HSS・HYDRAULIC PUMP TVC SOLENOID: DISCONNECTION (KA))

TROUBLESHOOTING ERROR CODE DXA0KA ERROR CODE DXA0KA (HSS HYDRAULIC PUMP TVC SOLENOID: DISCONNECTION (KA)) Circuit diagram related to TVC solenoid 20-542 D85EX-15 (1) Action code Error code C ontroller code Trouble and sion HSS • Hydraulic pump TVC solenoid: Disconnection (KA) (Steering and transmission controller system) E01 DXA0KA Steering transmis Contents of trouble • When signal is output to TVC solenoid circuit, any current does not flow. Action of controller • Stops outputting to TVC solenoid circuit. Problem that appears on machine • If the engine is loaded while its speed is low, it stalls. Related information • Output (Current) to TVC solenoid can be checked in monitoring mode.

(Code 01300, 01301: TVC solenoid output current) • Method of reproducing service code: Turn starting switch ON. Possible cause and standard value in normal state Cause Defective TVC solenoid (In 1 ternal disconnection) Disconnection in wiring har ness (Disconnection in wir- 2 s ing or defective contact in connector) Short circuit with power 3 source in wiring harness (Contact with 24V circuit) Defective steering and 4 transmission controller Standard value in normal state/Remarks on troubleshooting aPrepare with starting switch OFF, then carry out troubleshooting - without turning starting switch ON.

TVC (male) Resistance Between (1) – (2) 9 – 19z Resistance 9 – 19z aPrepare with starting switch OFF, then carry out troubleshooting - without turning starting switch ON. Wiring harness between STC3 (female) (17) – Resistance Max. 1z TVC (female) (1) Wiring harness between STC3 (female) (23) – Resistance Max. 1z TVC (female) (2) Resistance Max. 1z Resistance Max. 1z aPrepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Short circuit of wiring harness between STC3 (female) (17) – TVC (female) (1) with chassis Voltage Max. 1V ground Voltage Max. 1V aPrepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting.

STC3 (female) Resistance Between (17) – (3) 9 – 19z Resistance 9 – 19z