Komatsu — ERROR CODE [DXA0KB] (HSS・ HYDRAULIC PUMP TVC SOLENOID: SHORT CIRCUIT (KB))

TROUBLESHOOTING ERROR CODE DXA0KB ERROR CODE DXA0KB (HSS HYDRAULIC PUMP TVC SOLENOID: SHORT CIRCUIT (KB)) Circuit diagram related to TVC solenoid D85EX-15 20-543 (1) Action code Error code C ontroller code Trouble and sion HSS • Hydraulic pump TVC solenoid: Short circuit (KB) (Steering and transmission controller system) E01 DXA0KB Steering transmis Contents of trouble • When signal was output to TVC solenoid circuit, abnormal current flowed. Action of controller • Stops outputting to TVC solenoid circuit. Problem that appears on machine • If the engine is loaded while its speed is low, it stalls. Related information • Output (Current) to TVC solenoid can be checked in monitoring mode.

(Code 31623, 31624: Cooling fan solenoid output current) • Method of reproducing service code: Turn starting switch ON. Possible cause and standard value in normal state Cause Defective TVC solenoid (In 1 ternal short circuit) Short circuit with chassis 2 ground in wiring harness s (Contact with ground circuit Short circuit in wiring har- 3 ness (with another wiring harness) Defective steering and 4 transmission controller Standard value in normal state/Remarks on troubleshooting aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. - TVC (male) Resistance Between (1) – (2) 9 – 19z Between (1) – chassis ground Min. 1Mz Resistance 9 – 19z Min.

1Mz aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Short circuit of wiring harness between STC3 Min. ) (female) (17) – TVC (female) (1) with chassis Resistance 1Mz ground Resistance Min. 1Mz aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Short circuit in wiring harness between STC3 (female) (17) – TVC (female) (1) with wiring Min. Resistance harness between STC3 (female) (3) – TVC (fe- 1Mz male) (2) Resistance Min. 1Mz aPrepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting.

STC3 Resistance Between (17) – (3) 9 – 19z Between (17) – chassis ground Min. 1Mz Resistance 9 – 19z Min. 1Mz