Komatsu — E-8 WHILE THE PREHEATER IS OPERATING , THE PREHEATING PILOT LAMP DOES NOT COME ON

TROUBLESHOOTING E-8 E-8 WHILE THE PREHEATER IS OPERATING, THE PREHEATING PILOT LAMP DOES NOT COME ON. D85EX-15 20-615 (1) Trouble • While the preheater is operating, the preheating pilot lamp does not come on. Related information aThis troubleshooting describes the procedures to be followed when the preheating lamp doe not come on. (When the preheater mounting section is not heated, carry out the troubleshooting of “The preheater does not work.”) • For preheating, both the “Automatic Preheating Function” and the “Manual Preheating Function” are available. Even when either function is performed, the preheating lamp comes on.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Disconnection of wiring har- ness (Disconnection in wir- ing or defective contact in connector) aPrepare with the starting switch OFF, then carry out troubleshooting without turning the starting switch ON. Wiring harness between S03 (female) (9) and heater relay HT/B (B) terminal Resistance Max. 1z 2 Ground fault of wiring har- ness (Contact with ground circuit) aPrepare with the starting switch OFF, then carry out troubleshooting without turning the starting switch ON.

Between wiring harness between S03 (female) (9) and heater relay HT/B (B) terminal and ground Resistance Min. 1Mz 3 Defective monitor panel aPrepare with the starting switch OFF, then turn the starting switch ON and carry out troubleshooting. S03 Voltage Between (9) and ground ON Max. 1V HEAT Min. approximately 7V