TROUBLESHOOTING E-9 E-9 THE ENGINE WATER TEMPERATURE GAUGE DOES NOT INDICATE NORMALLY. Circuit diagram related to engine water high temperature sensor D85EX-15 20-617 (1) Trouble (1) • The engine water temperature gauge does not indicate normally. • Related information • Signals of the engine water high temperature sensor are sent and received from the engine controller through communication. When any abnormality occurred in the engine hot water temperature sensor system, the failure code [DGE2KX] is displayed sometimes.
Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting The engine water high tem- perature sensor is defec- 1 tive. (Internal disconnection or short circuit) aPrepare with the starting switch OFF, then carry out troubleshooting without turning the starting switch ON. TWH (male) Resistance Between (1) and (2) 3.5k – 90kz Between (1) (2) and ground Min. 1Mz Disconnection of wiring har- ness (Disconnection in wir- 2 ing or defective contact in connector) aPrepare with the starting switch OFF, then carry out troubleshooting without turning the starting switch ON.
Wiring harness between EGC2 (female) (27) and TWH (female) (1) Resistance Max. 1z Wiring harness between EGC2 (female) (39) and TWH (female) (2) Resistance Max. 1z Ground fault of wiring har- 3 ness (Contact with ground circuit) aPrepare with the starting switch OFF, then carry out troubleshooting without turning the starting switch ON. Between wiring harness (between EGC2 (fe- male) (27) and TWH (female) (1)) and ground Resistance Min. 1Mz Hot short circuit of wiring 4 harness (Contact with 24V circuit) aPrepare with the starting switch OFF, then turn the starting switch ON and carry out troubleshooting.
Between wiring harness (between EGC2 (fe- male) (27) and TWH (female) (1)) and ground Voltage Max. 1V 5 Defective engine controller aPrepare with the starting switch OFF, then carry out troubleshooting without turning the starting switch ON. EGC2 (female) Resistance Between (27) and (39) 3.5k – 90kz Between (27) (39) and ground Min. 1Mz 6 Defective monitor panel This is an internal defect, which cannot be troubleshot.