TROUBLESHOOTING E-21 E-21 THE MONITOR PANEL CANNOT BE SET IN THE SERVICE MODE. D85EX-15 20-629 (1) Trouble • The monitor panel cannot be set in the service mode.
Related information Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective buzzer cancel switch system Since the buzzer cancel switch system is supposed to be out of order, carry out the troubleshooting of “The buzzer cancel switch does not work.” 2 Defective information switch system Since the information switch system is supposed to be out of order, car- ry out the troubleshooting of “The information switch does not work.” 3 Defective fuse FS2 (5) When the fuse FS2 (5) is cut off, a ground fault may have possibly oc- curred in the circuit.
4 Defective service switch (In- ternal short circuit or discon- nection) aPrepare with the starting switch OFF, then carry out troubleshooting without turning the starting switch ON. S24 Service switch Resistance Between (1) and (2), Between (5) and (4) OFF Min. 1Mz ON Max. 1z 5 Disconnection of wiring har- ness (Disconnection in wir- ing or defective contact in connector) aPrepare with the starting switch OFF, then carry out troubleshooting without turning the starting switch ON. Wiring harness between FS2 (5)outlet and S24 (1) Resistance Max. 1z Wiring harness between S24 (6) and ground Resistance Max. 1z Wiring harness between S03 (female) (16) and S24 (2) Resistance Max.
1z Wiring harness between STC1 (female) (6) and S24 (5) Resistance Max. 1z 6 Ground fault of wiring har- ness (Contact with ground circuit) aPrepare with the starting switch OFF, then carry out troubleshooting without turning the starting switch ON. Contact of wiring harness between FS2 (5) – S24 (1) – S03 (female) (5), (6) with ground. Resistance Min. 1z 7 Defective monitor panel (Gauge/lamp module) aPrepare with the starting switch OFF, then turn the starting switch ON and carry out troubleshooting. S03 Service switch Voltage Between (16) and ground OFF Max.
1V ON 20 – 30V 8 Defective steering and transmission controller aPrepare with the starting switch OFF, then turn the starting switch ON and carry out troubleshooting. STC1 Service switch Voltage Between (6) and ground OFF 20 – 30V ON Max. 1V