Komatsu — E-23 THE HEAD LAMP, REAR LAMP, AND RIPPER POINT LAMP DO NOT LIGHT UP

TROUBLESHOOTING E-23 E-23 THE HEAD LAMP, REAR LAMP, AND RIPPER POINT LAMP DO NOT LIGHT UP. 20-632 D85EX-15 (1) Trouble (1) • The head lamp does not light up. Related information Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective fuse (FS1-(3)) If the fuse is broken, the circuit probably has a grounding fault, etc. 2 Defective head lamp switch (Internal disconnection) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. FWL (male) Switch Resistance Between (2) – (3) OFF Min. 1 Mz ON Max.

1z 3 Disconnection in wiring har- ness (Disconnection in wir- ing or defective contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between FWL (female) (2) – FS1-(3) outlet Resistance Max. 1z Wiring harness between FWL (female) (3) – 203 (female) (1) Resistance Max. 1z Wiring harness between FWL (female) (3) – 204 (female) (1) Resistance Max. 1z 4 Short circuit with chassis ground in wiring harness (Contact with ground circuit) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.

Contact of wiring harness between FWL (fe- male) (2) – FS1-(3) outlet with ground Resistance Min. 1 Mz Trouble (2) • The rear lamp and ripper point lamp do not light up. Related information Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective fuse (FS1-(4)) If the fuse is broken, the circuit probably has a grounding fault, etc. 2 Defective rear lamp switch (Internal disconnection) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. RWL (male) Switch Resistance Between (2) – (3) OFF Min. 1 Mz ON Max.

1z 3 Disconnection in wiring har- ness (Disconnection in wir- ing or defective contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between RWL (female) (2) – FS1-(4) outlet Resistance Max. 1z Wiring harness between RWL (female) (3) – 224 (female) (1) Resistance Max. 1z Wiring harness between RWL (female) (3) – 226 (female) (1) Resistance Max. 1z 4 Short circuit with chassis ground in wiring harness (Contact with ground circuit) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.

Contact of wiring harness between RWL (fe- male) (2) - FS1-(4) outlet with ground Resistance Min. 1 Mz