TROUBLESHOOTING E-24 20-640 D85EX-15 (1) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 7 Disconnection or short cir- cuit with chassis ground in wiring harness (Disconnec- tion in wiring or defective contact in connector or con- tact with ground circuit) Wiring harness between fuse (4) – CN12 (fe- male) (2), (3) Resistance Max. 1z Contact of wiring harness between fuse (4) – CN12 (female) (2), (3) with ground Resistance Min. 1 Mz Wiring harness between fuse (4) – CN32 (fe- male) (3) – CN37 (female) (3) Resistance Max.
1z Contact of wiring harness between fuse (4) – CN32 (female) (3) – CN37 (female) (3) with ground Resistance Min. 1 Mz Wiring harness between CN32 (female) (5) – CN37 (female) (1) Resistance Max. 1z Contact of wiring harness between CN32 (fe- male) (5) – CN37 (female) (1) with ground Resistance Min. 1 Mz Wiring harness between CN32 (female) (6) – ground Resistance Max. 1z Wiring harness between CN37 (female) (2) – ground Resistance Max. 1z