Komatsu — E-24 MALFUNCTION OF WIPERS

TROUBLESHOOTING E-24 20-644 D85EX-15 (1) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 7 Disconnection or short cir- cuit with chassis ground in wiring harness (Disconnec- tion in wiring or defective contact in connector or con- tact with ground circuit) Wiring harness between fuse (6) - CN13 (fe- male) (2), (3) – CN17 (4) – connector (female) (4) just before motor – CN13 (female) (2), (3) Resistance Max. 1z Contact of wiring harness between fuse (6) - CN13 (female) (2), (3) – CN17 (4) – connector (female) (4) just before motor – CN13 (female) (2), (3) with ground Resistance Min.

1 Mz Wiring harness between fuse (6) – CN30 (fe- male) (3) Resistance Max. 1z Contact of wiring harness between fuse (6) – CN30 (female) (3) with ground Resistance Min. 1 Mz Wiring harness between connector (female) (3) just before motor – CN17 (3) – CN30 (female) (5) Resistance Max. 1z Contact of wiring harness between connector (female) (3) just before motor – CN17 (3) – CN30 (female) (5) with ground Resistance Min. 1 Mz Wiring harness between CN30 (female) (6) – ground Resistance Max. 1z Wiring harness between connector (female) (1) just before motor – CN17 (1) – ground Resistance Max. 1z